| MECHANICAL
FEATURES
|
|
Installation On DIN rail (46277-3), 35 mm width or Bezel
96 x 96 mm, Cutout 92 x 92 mm, Depth 110 mm |
|
Weight 300 gm (approx.) |
|
Protection degree IP50(front), IP20(terminals)
|
| |
| DISPLAY |
|
16 x 2 Alphanumeric backlit display or 7 segment LED display.
|
|
LED display. |
| |
| PARAMETERS
DISPLAYED |
|
Voltages (L - N): V1, V2, V3 & Summation |
|
Voltages (L - L): V1-V2, V2-V3 & V3-V1 |
|
Current: i1, i2, i3 & Summation |
|
Power Factor: Cos L1, COs L2, COs L3 & Summation |
|
Frequency: Hz |
|
Power: KW1, KW2, KW3 & Summation. |
|
Apparent Power: KVA1, KVA2, KVA3 & Summation. |
|
Reactive Power: KVAr1, KVAr2, KVAr3 & Summation |
|
Energy KWh (Import / Export) |
|
Energy KVArh (Inductive) or KVArh (cap.) |
|
Max. Current: I1 Max., I2 Max., I3 Max. |
|
Max. Volt: V1 Max., V2 Max. & V3 Max. |
|
Average Power & Current. |
|
Maximum Average Power & Current. |
| |
| FEATURES |
|
Auto Rangeing (example : W to KW to MW) |
|
Auto Scrolling |
|
Default Display will be V1, V2, V3 & Summation Page. |
| |
| SITE
PROGRAMMABLE |
|
CT & PT ratio |
|
Phase Selection |
| a)
Single Phase |
| b)
Three Phase |
| i)
3 Phase 3 Wire |
| ii)
3 Phase 4 Wire |
|
Scrolling |
| a)
Manual (Up/Down Keys) |
| b)
Auto (Time duration for each page site Settable) |
|
Identification
of each unit when cascaded. (RS 485) |
|
Password
Protection software facility incorporated |
| |
| ADDITIONAL
FEATURES WITH NEW MODULES |
|
Harmonics analysis |
| |
| POWER
SUPPLY |
Data Retention All programming data and energy consumptions
are stored in EEPROM.
Data retention 10 years w/o power supply. |
| |
| ENVIRONMENT |
|
Oper. Temperature :
-10°C to +50°C |
|
Oper. Humidity :
< 75% RH (non-condensing) |
|
Storage
temperature : -25°C
to + 60°C |
| |
| COMMUNICATION |
|
RS485
Other on request |
| |
| REFERENCE
STANDARDS |
|
IEC
348 / VDE0110 |
|
8°C
/336/EEC - 73/23/EEC and following updates. |
| |
| ELECTROMAGNETIC
COMPATIBILITY |
|
IEC
1036/IS 13779 (Class 1.0) |
|
IEC
678/CBIP-88 (Class 0.5S / 0.2S) |
| |
| HUMIDITY |
|
95%
RH Condensing |
| |
| SINGLE
PHASE LOAD MANAGER |
| State
of the Art Design using LCD and display true RMS values. |
| |
| Specifications
: |
| Functions |
Ranges
(115 / 230 V ) |
Accuracy |
| Vrms |
95.0
-125 Vrms |
0.2
% |
| |
190.0
- 250.0 Vrms |
|
| Arms |
0.00
- 15.0 Arms |
0.5
% |
| Watt |
1875
Watt / 3750 Watt |
0.5
% |
| VA |
1875
VA / 3750 VA |
0.5
% |
| Frequency |
47.0
- 63.0 Hz |
±
0.1 Hz |
| Powerfactor |
0.00
- 1.00 |
0.01 |
| KWh |
0.00
- 9999 |
0.5
% |
| KWh
hour |
0.00
- 9999 |
30
ppm |
|
| |
| Specifications
: |
| Functions |
Range
|
Accuracy |
| Vrms |
200.00
- 500.00 Vrms |
0.5
% |
| Arms |
1A/5A
100 Arms - 1600 Arms site selectable |
0.5
% |
| Watt |
800
kW (max.) |
1
% |
| Frequency |
47.0
- 63.0 Hz |
±
0.1 Hz |
| Powerfactor |
0.00
- 1.00 |
0.01 |
|
| |
| Size